Invalid specification for system parameter LOCAL_LISTENERORA-00119: invalid specification ORA-00132: syntax error
ISSUE:
sqlplus / as sysdba
SQL*Plus: Release 12.1.0.2.0 Production on Thu 12 07:37:51 2018
Copyright (c) 1982, 2014, Oracle. All rights reserved.
Connected to an idle instance.
SQL> startup
ORA-00119: invalid specification for system parameter LOCAL_LISTENER
ORA-00132: syntax error or unresolved network name 'LISTENER'
SQL>
CAUSE
Your INIT file by default will look for an ALIAS name of Listener in
TNSNAMES.ora which doesnt exist in the file.
SOLUTION
#OPTION:1
Hence create a same entry for LISTENER in tnsnames.ora file.
LISTENER =
(DESCRIPTION_LIST =
(DESCRIPTION =
(ADDRESS = (PROTOCOL = TCP)(HOST = localhost)(PORT = 1521))
)
)
#OPTION 2:
You can directly insert the entry of Local Listener in the INIT file like below.
*.local_listener='(ADDRESS=(PROTOCOL=TCP)(HOST=localhost)(PORT=1521))'